Brooks 5850S · SLA5850 · RS-485 · S-protocol

A second life for proven hardware.

FlowHub is software modernisation for your existing Brooks mass flow controllers. Extend their life cycle, save on replacement and unlock powerful IT/OT integration — including AI — without interrupting your process.

0
new MFCs
0
recalibrations
1
serial-to-Ethernet converter
100%
writes with readback
01Value proposition
01

Modernise

Web dashboard, secure API, roles and audit on top of hardware that has served reliably for decades.

02

Extend the life cycle

Your 5850S and SLA5850 stay in place. No new controllers, no recalibration, no downtime.

03

IT/OT integration incl. AI

Process data opened up to MES, ERP, data warehouses and AI applications — within reach for SMEs.

02Interactive dashboard simulator

Select a controller, write a new setpoint and watch the readback arrive. Or view a running batch on the Batch / recipe tab.

03Replacement vs. modernisation

Replace with new MFCs

  • −Purchase of new controllers per channel
  • −Production or lab downtime during the changeover
  • −Recalibration and requalification of the process
  • −Proven, working hardware is written off

Modernise with FlowHub

  • +One serial-to-Ethernet converter on the existing RS-485 bus
  • +Installed alongside the running process
  • +Existing calibration remains valid
  • +Modern dashboard, API and audit available immediately
04Reliability & architecture
Brooks 5850S / SLA5850 mass flow controller
01 · Brooks 5850S / SLA5850 mass flow controller
RS-485 ↔ Ethernet gateway
02 · RS-485 ↔ Ethernet gateway
S-protocol specification
03 · S-protocol specification
  [ MFC 5850S ]──┐
  [ SLA5850   ]──┼── RS-485 (half-duplex) ──[ serial↔Ethernet ]── TCP ──[ FlowHub server ]──┬── Web dashboard (WebSocket)
  [ MFC 5850S ]──┘        Brooks S-protocol                                                 ├── REST API
                                                                                             └── IT/OT · MES · ERP · AI

Brooks S-protocol

Framing, addressing and checksum per the official reference. Unknown unit codes are never guessed.

Half-duplex bus

One transaction at a time. Writes take priority; polls are rescheduled, never dropped.

Roles & sessions

Viewer, operator and admin. Revocable sessions and rate limiting.

Audit logging

Every change recorded with old and new value, exportable as CSV.

Existing & tested
  • ✓Live flow, temperature, setpoint and valve position
  • ✓Setpoint and valve override with mandatory readback
  • ✓Configuration: units, setpoint source, soft start
  • ✓Recipes & batches with time, flow and manual triggers
  • ✓Roles, audit trail and CSV export
  • ✓Health monitoring: converter vs. dashboard failure
  • ✓Protocol simulator for development without hardware
Possibilities & future integrations
  • →Integration with MES, ERP or historians via the API
  • →AI applications: anomaly detection, predictive maintenance, process optimisation
  • →Dashboards and reporting in existing BI environments
  • →Totalizer and gas-switch triggers (phase 2)

Depends on your environment and external systems; scoped per project.

STATUS

FlowHub has been tested against the official Brooks manuals and a protocol simulator, but has not yet been validated on physical hardware. Bench validation on your device family and firmware is the final step before production use.

05Next step

Request bench validation or a pilot

Running Brooks 5850S or SLA5850 controllers? Together we validate FlowHub on your hardware and firmware, and explore which IT/OT and AI integrations add value.